National Repository of Grey Literature 11 records found  1 - 10next  jump to record: Search took 0.01 seconds. 
Solution technology of production "Válec elementu vstřikovacího čerpadla"-part in condition firm Motorpal Jihlava.
Havel, Marian ; Polzer, Aleš (referee) ; Kalivoda, Milan (advisor)
This thesis is intended on optimalization of industrial process the barrel element of injection pump. Existing technology, mainly special-purpose machines, will be replaced with modern methods with utilization CNC turning machines and new efficient machines for finishing operations, especially for finalization the main hole of the barrel. Thereinafter it will be worked suggestions critical operations, which hands main function element and it is necessary their optimalization in light of work difficulty and ecology.
Study of bearing noise regarding accuracy of machining
Studýnka, Pavel ; Sabo, Karol (referee) ; Klapka, Milan (advisor)
This bachalor thesis deals with connection between the quality of surface of raceways of a bearing and vibrations in operation. This thesis describes basic geometrical parameters of a bearing that have main influence on its resulting quality and vibrations. It presents methods to evaluate the quality of the raceways surfaces and their connection between them. As a part of the thesis is an experiment, which should prove, what is the connection between the measuring of quality of the surface of raceways and measuring the vibrations of bearings during the process, by the way used in the company KOYO Olomouc. The quality of raceways is evaluated on a measuring device MUK-F 300 and vibrations on IL 100R/2000.
Mechanical Analysis of the Influence of Fabrication Tolerances on Contact Conditions between the Acetabular Cup and the Femoral Head in Total Hip Replacement
Koukal, Milan ; Horyl, Petr (referee) ; Repko, Martin (referee) ; Janíček, Přemysl (referee) ; Florian, Zdeněk (advisor)
In endoprosthesis surgery there are typically a high percentage of implant defects, these can lead to failure of the whole prosthesis. One type of total hip replacement function loss is acetabular cup loosening from the pelvic bone. This disertation examines manufacture perturbations as one of the possible reasons for this kind of failure. Both dimension and geometry manufacturing perturbations of ceramic head and polyethylen cup were analyzed. We find that perturbations in the variables analysed here affect considered values of contact pressure and frictional moment. Furthermore, contact pressure and frictional moment are quantities affecting replacement success and durability. From obtained results it can be recommended to fit head and cup with a clearance of between 0 mm and 0.05 mm. It can not be recommend using interference type of fit because of strong deterioration of the contact conditions. Roundness perturbation of ceramic head should not exceed 0.025 mm.
Reducing vibration and noise of bearings
Nejeschleba, Martin ; Prostredník, Daniel (referee) ; Jankových, Róbert (advisor)
The diploma thesis deals with the issue of bearings noisiness. The bearings noisiness appears as a negative phenomenon in all the mechanical devices that generate any kind of movement. Analysis of this phenomenon enables to analyse the technical condition of the bearing and predict its defects as well. The theoretical part of the thesis is devoted to the vibration diagnostics and noisiness diagnostics, which are deeply linked. The practical part of the thesis deals with the real problem of the bearing’s noisiness in the engineering company. The main asset of this thesis is a design and successful implementation of the measures, which reduce noisiness of the selected type of the bearing.
Reducing vibration and noise of bearings
Nejeschleba, Martin ; Prostredník, Daniel (referee) ; Jankových, Róbert (advisor)
The diploma thesis deals with the issue of bearings noisiness. The bearings noisiness appears as a negative phenomenon in all the mechanical devices that generate any kind of movement. Analysis of this phenomenon enables to analyse the technical condition of the bearing and predict its defects as well. The theoretical part of the thesis is devoted to the vibration diagnostics and noisiness diagnostics, which are deeply linked. The practical part of the thesis deals with the real problem of the bearing’s noisiness in the engineering company. The main asset of this thesis is a design and successful implementation of the measures, which reduce noisiness of the selected type of the bearing.
Mechanical Analysis of the Influence of Fabrication Tolerances on Contact Conditions between the Acetabular Cup and the Femoral Head in Total Hip Replacement
Koukal, Milan ; Florian, Zdeněk (advisor)
In endoprosthesis surgery there are typically a high percentage of implant defects, these can lead to failure of the whole prosthesis. One type of total hip replacement function loss is acetabular cup loosening from the pelvic bone. This disertation examines manufacture perturbations as one of the possible reasons for this kind of failure. Both dimension and geometry manufacturing perturbations of ceramic head and polyethylen cup were analyzed. We find that perturbations in the variables analysed here affect considered values of contact pressure and frictional moment. Furthermore, contact pressure and frictional moment are quantities affecting replacement success and durability. From obtained results it can be recommended to fit head and cup with a clearance of between 0 mm and 0.05 mm. It can not be recommend using interference type of fit because of strong deterioration of the contact conditions. Roundness perturbation of ceramic head should not exceed 0.025 mm.
Mechanical Analysis of the Influence of Fabrication Tolerances on Contact Conditions between the Acetabular Cup and the Femoral Head in Total Hip Replacement
Koukal, Milan ; Horyl, Petr (referee) ; Repko, Martin (referee) ; Janíček, Přemysl (referee) ; Florian, Zdeněk (advisor)
In endoprosthesis surgery there are typically a high percentage of implant defects, these can lead to failure of the whole prosthesis. One type of total hip replacement function loss is acetabular cup loosening from the pelvic bone. This disertation examines manufacture perturbations as one of the possible reasons for this kind of failure. Both dimension and geometry manufacturing perturbations of ceramic head and polyethylen cup were analyzed. We find that perturbations in the variables analysed here affect considered values of contact pressure and frictional moment. Furthermore, contact pressure and frictional moment are quantities affecting replacement success and durability. From obtained results it can be recommended to fit head and cup with a clearance of between 0 mm and 0.05 mm. It can not be recommend using interference type of fit because of strong deterioration of the contact conditions. Roundness perturbation of ceramic head should not exceed 0.025 mm.
Study of bearing noise regarding accuracy of machining
Studýnka, Pavel ; Sabo, Karol (referee) ; Klapka, Milan (advisor)
This bachalor thesis deals with connection between the quality of surface of raceways of a bearing and vibrations in operation. This thesis describes basic geometrical parameters of a bearing that have main influence on its resulting quality and vibrations. It presents methods to evaluate the quality of the raceways surfaces and their connection between them. As a part of the thesis is an experiment, which should prove, what is the connection between the measuring of quality of the surface of raceways and measuring the vibrations of bearings during the process, by the way used in the company KOYO Olomouc. The quality of raceways is evaluated on a measuring device MUK-F 300 and vibrations on IL 100R/2000.

National Repository of Grey Literature : 11 records found   1 - 10next  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.